Sale!

Alderon 2010628 Check It Single Phase Simplex 120/230VAC 1 – 7A FLA

Original price was: $716.00.Current price is: $214.80.

SKU: ID2248118 Category: Tag:

Description

Pump Full Load (Amps): 1-7, Base Model: Single Phase Simplex, Demand Dosing, Voltage (VAC): 120/230

Alderon, 2010628,Check It CKIT1S230C7+3AGHPS20 Single Phase Simplex, Demand Dosing, 120/230VAC, 1 – 7 FLA, Type 4X, Circuit Breaker, (3) 20′ Normally Open Pipe Clamp Control Float Switches

Features:

  • Type 4X Enclosure, Indoor or Outdoor Use, Pad-Lockable
    • Standard Enclosure Size 10″ x 8″ x 4″ (inches)
    • Opaque Door, Alarm Beacon with Red Flashing LEDs
    • Alarm Buzzer and Alarm Test/Silence Switch
  • Pump Circuit Breaker and IEC Contactor Pump Starter
    • Pump Circuit Breakers for Pump Disconnect
  • Beacon with Vibrant Multi-Color LEDs
    • Green (normal/pump run), Red (alarms), and Amber (error/HOA off)
    • Event LEDs will flash and normal state LEDs will be solid
  • System Status LEDs (circuit board)
  • Automatic Resettable Alarm and Control Fuses
  • Built-In Printed Circuit Board Surge Protection
    • Conformal Coated for Reliable Thermal and Moisture Protection
  • Easily Change Configurations
    • Sensor Error Input, Automatic or Manual Alarm Reset, Redundant Start Enable, and System Normal Beacon Disable
  • Included Auxiliary “Dry” Contacts
    • Normally Open or Closed, General Alarm (any) plus Power Loss
  • Hand-Off-Auto (HOA) Pump Selector Switch
    • Off Reminder, Yellow Flashing LEDs (beacon)
  • Configure/Test Button (interior, circuit board)
    • Activate Alarm Test, Clear Alarms, and Enable or Disable System Configuration Settings
  • Exterior Test/Silence Switch
    • Activated and Deactivated less than 5-seconds, Activates Alarm Test
    • Activated more than 5-seconds, Clears all Alarms
    • Silence Buzzer during Alarm

For more information, please see Data Sheet and Quick Start Quide

Base Model Single Phase Simplex, 120/230VAC, Pump Circuit Breaker
Pump Full Load Amps (FLA) 1 – 7 Amps
Number Of Control Switches (floats) (3) Control Switches – Off, Start, and Liquid Level Alarm
Activation Type High Level, Normally Open (Pump Down)
Mounting Method Pipe Clamp, Stainless Steel
Enclosure Size 10 x 8 x 4
Overall Width (W) 10.27
Overall Height (H) 13.69
Overall Depth (d) 5.01
Mounting Width (M1) 6.13
Mounting Height (M2) 10.75

Reviews

There are no reviews yet.

Be the first to review “Alderon 2010628 Check It Single Phase Simplex 120/230VAC 1 – 7A FLA”

Your email address will not be published. Required fields are marked *