Description
Alderon, 2010881, FLEX FLXC3S460CO4-6-E3D1+3AGHPS20 Clear Door, Three Phase Simplex, 208/230/460VAC, 4 – 6 Amps, Enclosure Size 14″ x 12″ x 6″, Main Disconnect – 30 Amp, (3) Altra Gold Control Switches, Normally Open, Stainless Steel Pipe Clamps, 20′ Cable
- Type 4X Enclosure, Indoor or Outdoor Use, Pad-Lockable
- Standard Enclosure Size 12″ x 10″ x 6″ (inches)
- Clear Door, View OLED Screen with Alarm and Status Indicator LEDs
- Alarm Buzzer and Alarm Test/Silence Switch
- Pump Motor Protective Switch (MPS) and IEC Contactor
- Combination Circuit Breaker, IEC Contactor Pump Starter, and Overload Relay
- Motor Protective Switch includes Adjustable Pump Amp Range which Protects the Pump from Overcurrent Damage
- Motor Protective Switch for Pump Disconnect
- Vibrant Multi-Color LEDs (select indicators listed)
- Green (normal), Red (alarms), Blue (pump run), and Red/Yellow (error)
- Automatic Resettable Alarm and Control Fuses
- Built-In Printed Circuit Board Surge Protection
- Conformal Coated for Reliable Thermal and Moisture Protection
- Easily Change Configurations
- Demand Dosing, Timed Dosing, Transducer Settings, Enable Pump Exerciser, and Seal Fail Alarm or Pump Shutdown
- Sensor Options (signaling device)
- Field Wire up to (5) Digital Inputs
- Low Alarm/Redundant Off, Off, Lead, and Lag/High Alarm
- Configure 5th Input for a 4-20mA Submersible Transducer or Digital Input for Auxiliary Switch, or (5) Float System (separates Lag and High Alarm)
- Statistic Tracking (each pump)
- Pump Elapsed Time, Min/Max/Avg Pump Run Times, Pump Cycle Counter, Total Gallons Pumped, High Level Stats, and More
- Included Auxiliary “Dry” Contacts
- Pump 1 Run, Pump 2 Run, and General Alarm
- Configurable Reverse Operated for General Alarm plus Power Loss
- Hand-Off-Auto (HOA) Pump Selector Switch (each pump)
- Off Reminder, Yellow Flashing LEDs (beacon)
- Configurable Pump Disable
- Scroll Wheel and Digital Display (password protected settings)
- Navigate Menu, Access Statistics Tracking, Configure Settings, and Displays System Information on OLED Screen
- Exterior Test/Silence Switch
- Quick View of Pump and Alarm Stats
- Check Alarm LEDs and Buzzer or Silence Buzzer during Alarm
For more information, please see Data Sheet and Quick Start Quide
| Base Model | Clear Door, Three Phase Simplex |
| Voltage | 208/230/460VAC |
| Pump Full Load Amps (FLA) | 4 – 6 Amps |
| Options | Main Disconnect – 30 Amp |
| Number Of Control Switches (floats) | (3) Control Switches – Off, Start, and High Level Alarm |
| Mounting Method | Pipe Clamp, Stainless Steel |
| Cable Length (feet; standard) | 20′ Cable Length |
| Enclosure Size | 14 x 12 x 6 |
| Overall Width (W) | 14.01 |
| Overall Height (H) | 15.85 |
| Overall Depth (D) | 7.27 |
| Mounting Width (M1) | 10.24 |
| Mounting Height (M2) | 14.83 |





Reviews