Sale!

Alderon SP32-010 Suspension Probe Three Phase Duplex 1.0-1.6 Amps FLA

Original price was: $2,090.00.Current price is: $627.00.

SKU: ID2248511 Category: Tag:

Description

FLA Ranges: 1.0-1.6, Quantity of 20 Feet Probes: 5

Alderon, SP32-010, Suspension Probe Control Panel, Three Phase Duplex, 208/230/460VAC, 1.0-1.6 FLA, Type 4X, Motor Protective Switch, (5) 20′ Probes (Reference, Off, Lead, Lag, High Level Alarm)

Features:

  • Enclosure – Thermoplastic, Type 4X
  • HOA Switch – Automatic or manual pump control
  • Green Pump Run Indicator
  • Fused Control Disconnect (Provides on/off function)
  • Alternating Relay (Duplex only)
  • Multi-Tap Transformer
  • IEC Motor Contactor
  • Motor Protective Switch
  • Field Wiring Terminal Block
  • Terminal Block Field – Wiring label
  • Ground Lug
  • Suspension Probe Sensors
  • Probe Sensors Labeled – For easy field wiring
  • Alarm Fuse (Model Specific)
  • Alarm Indicator (Model Specific)
  • Alarm Buzzer – Loud 100 db warb
  • Auto Reset – Horn silence (Model Specific)
  • Test/Silence Switches – (Model Specific)
  • Industrial Control Panel (UL 508A)

The Suspension Probe Three Phase Duplex control panel is used to operate two (2) pumps for water, dewatering, and storm water applications. Comes in 208/230/460VAC, 1.0-1.6 FLA Ranges, and a Type 4X (outdoor) enclosure. The control panel includes five (5) 20′ single point suspension probes, a hand-off-auto (HOA) switch with pump run indicator for each pump, a drain-fill selector switch, and an alternating relay with load selector switch plus load indicators. The incoming and pump power must match system voltage with conduit connections (required) per local codes. Refer to included electrical schematic for complete wiring and voltage information.

The control panel is operated by the included suspension probes for reference point, pump stop, pump lead, pump lag, and high/low liquid level alarm. As the liquid level rises/recedes activating the pump lead probe, the pump will start and continue to run until the pump stop probe is deactivated to complete the pump cycle. If the pump lag probe is activated, the second pump will start and the pump(s) will continue to run until the pump stop probe is deactivated. If the high/low level probe is activated, the beacon will illuminate and buzzer will annunciate. If the alarm test/silence switch is toggled to “silence” during an alarm condition, it will silence the buzzer while the alarm beacon remains illuminated. The alarm condition will reset when the high/low level probe deactivates and the system will auto reset for the next alarm cycle. Test alarm once a month to ensure system integrity, toggle the alarm test/silence switch to “test”, the beacon should illuminate and buzzer should annunciate. Use the drain-fill selector switch to easily convert from a pump down (drain) to pump up (fill) application without having to rewire the suspension probes.

Auxiliary contacts can be included to connect to a building automation system (BAS) or SCADA system and phone dialers for remote notification of an alarm condition and/or pump run events.

For more information, please see Data Sheet and Standard Control Panel Accessories

Suspension Probe – Three Phase Duplex, 5-Probes, Alarm Activation
Primary Power 208/230/460VAC, 1,0-1,6 Range, 60 Hz (208VAC, 230VAC, or 460VAC pump)
Phase/Pump Type Three Phase, Duplex
Terminal Blocks 120/230VAC, 30A, 50A, 65A, and 85A
IEC Motor Contactor 208/230/460VAC, 18A, 25A, or 32A, 50/60 Hz; 3-Pole, Normally Open
Motor Protective Switch 208/230/460VAC, 50/60 Hz; 1,0 FLA – 1,6 FLA ; 3-Pole, Normally Open
Control Transformer 50VA, 208/230/460VAC; Fuses, 600VAC, FNQ-R, 0.5A, Class CC
Liquid Level Relay 0.25HP at 120VAC; 10A, 240VAC or 7A, 28VDC | Single Pole, Double Throw | Sensitivity Range 4.7K – 100K OHMS | Status indicator for power/relay on (green/red)
Alarm Beacon 15 Watt, Polycarbonate (red)
Alarm Buzzer 120VAC, 95 dB at 2-feet
Control Relays 120VAC, 12A, Four Pole, Double Throw
Alternating Relay 120VAC, 10A, 2-LED load indicators (red); Double Pole, Double Throw
Fuses (fast acting type AGC) 250VAC maximum, 1 Amp, 5mm x 20mm
Hand-Off-Auto Switch 120VAC, 6A, Single Pole, Double Throw
Drain-Fill Switch 120VAC, 6A, Single Pole, Double Throw
Test/Silence Switch 120VAC, 6A, Single Pole, Double Throw
Pump Run Indicators 125VAC, 3 Watt, Neon (green)
Enclosure Thermoplastic; 16 x 14 x 8; Type 4X, Outdoor; Enclosure Screws
Suspension Probes 120/230VAC, bare lead, 18 gauge, 2-conductor; (5) 20’ Single Point Electrode Probes (ferrule); 316 stainless steel, 1-inch diameter
Certifications UL 508 (US and Canada)

Reviews

There are no reviews yet.

Be the first to review “Alderon SP32-010 Suspension Probe Three Phase Duplex 1.0-1.6 Amps FLA”

Your email address will not be published. Required fields are marked *